Every liver lesion, followed from one scan to the next.

Scanvero finds and measures liver metastases on each CT scan, links them across a patient's follow-up scans, and reports what changed. The radiologist confirms every link before a number appears.

Research software from Scanvero Ltd. Not for clinical use.

Slices from the Scanvero research build on public research CT (CRLM-CT-1006). Not patient care data.

The same patient, scanned every few months.

When colorectal cancer spreads to the liver, patients are re-scanned every 2 to 3 months through chemotherapy, ablation and surgical planning. Each time, someone has to find every lesion again and work out which is which.

CT
Baseline scanLesions found and measured
Rx
TreatmentChemotherapy or ablation
CT
Follow-up scanEvery lesion found again
?
Which is which?Matched by hand today
CT
And againEvery 2 to 3 months

SlowSeveral lesions, several scans, all re-measured by hand at each visit.

InconsistentTwo readers measuring the same lesion often get different answers.

ConsequentialThe size change decides whether treatment is working.

Why it matters.

More patients, more scans, fewer radiologists, and measurements that vary between readers. Each figure links to its original source.

48,213

new bowel cancer cases a year in the UK.

Cancer Research UK, 2019 and 2021-2022
26.5%

developed liver metastases within five years, in a population study of 1,026 patients.

Engstrand et al., BMC Cancer 2018 (Stockholm)
±30%

how far two radiologists' measured change in one lesion can differ, wider than the 20% growth that counts as progression.

Yoon et al., Eur J Cancer 2016, 12 studies
32%

fewer radiologists than the UK needs today, forecast to reach 40% by 2030.

Royal College of Radiologists, 2025 census

No confirmation, no number.

Scanvero would rather show "not available" with a reason than a plausible number nobody has checked. Try it: the change in size appears only once the link is confirmed.

  • Contrast phase not confirmed: measurement withheld.
  • Lesion link not confirmed: change withheld.
  • Result cannot be traced to its source images: result withheld.

Lesion 2, segment VII

Illustration with example values
Baseline18 mm
Follow-up15 mm
Change in size
Not availableLink proposed, not yet confirmed

A demonstration of the rule, not output from a patient scan.

What we have measured so far.

Research results on public data, with pass marks written down before each test. Read the full evidence and its limits.

0.951

Liver outline overlap

Average Dice against reference outlines, with 1.17% average volume error, on 102 of 103 external colorectal cases (MCT-LTDiag, 1 excluded).

97.5%

Lesions over 20 mm found

And 78.5% of lesions 10 to 20 mm, on 103 external colorectal cases (MCT-LTDiag). False positives, 2.26 per scan, are still above target.

128/129

Lesion links correct

Expert outlines, in the 37 of 43 sealed scan pairs the alignment accepted; the other 6 were refused, not guessed. Public melanoma longitudinal research set.

These are research results on public data, not clinical validation.